  • NH-YJV22耐火电力电缆.jpg

NH-YJV22 fire-resistant power cable

<p><strong>Model:</strong>Ng-yjv22<br> <strong>Material:</strong>High quality oxygen-free copper<br> <strong>Voltage:</strong>0.6/1KV<br> <strong>Specifications:</strong>1 core -5 core, 2 1 core, 3 1 core, 3 2 core, 4 1 core<br> <strong>Product Application:</strong>Home improvement power distribution, urban power distribution, engineering power distribution</br></br></br></br></p>

Key words:

Classification:

  • Product Description
  • 1. product use

    This product is suitable for fixed installation of rated voltage 0.6/1kV in distribution networks or industrial installations.

    Executive standard of 2. products

    Fire-resistant power cables are manufactured according to enterprise standards, and the fire-resistant characteristics meet the requirements of GB/T19666-2019.

    3. product characteristics

    Long-term allowable working temperature of cable conductor: PVC insulation 70 ℃, XLPE insulation 90 ℃.

    The temperature of the cable during short circuit (duration not exceeding 5s) is 160 ℃ for PVC insulation (140 ℃ for cross-section greater than 300mm2) and 250 ℃ for cross-linked polyethylene insulation.

    When laying cables, the ambient temperature should not be lower than 0 ℃, and preheating should be carried out when the temperature is lower than 0 ℃.

    4. product specifications

    Name Model Specifications
    Copper conductor XLPE insulated power cable YJV 1 core -5 core, 2 1 core, 3 1 core, 3 2 core, 4 1 core
    Copper conductor XLPE insulated armored power cable YJV22 1 core -5 core, 2 1 core, 3 1 core, 3 2 core, 4 1 core
    Copper conductor XLPE insulated fire resistant power cable Ly yjv 1 core -5 core, 2 1 core, 3 1 core, 3 2 core, 4 1 core
    Copper conductor XLPE insulated fire-resistant armored power cable Ng-yjv22 1 core -5 core, 2 1 core, 3 1 core, 3 2 core, 4 1 core

    5. application sites

    The fire resistance of this product meets the requirements of GB/T19666-2019. Conductor DC resistance in accordance with the provisions of GB/T3956.

    The product is suitable for laying in indoor, tunnel and pipeline where fire resistance is required.

    It is suitable for high-rise buildings, hospitals, theaters, power stations, subways, tunnels, petrochemical industries and other places with special fire resistance requirements and places with a large population.

    6. product structure

Get Quote

Note: Please leave your email and our professionals will contact you as soon as possible!